Exposure rack
5°
Subarctic test site located in the north of Sweden.
ISO 9223 - Measurement period: 2018-10-01 - 2019-10-01 Measuring inputed: 2022/08/23 | Steel | Zinc | Copper | Aluminium |
---|---|---|---|---|
ISO 9223 - Corrosion rate [g/m² year] | 38 | 4.4 | 1.7 | 0.3 |
Corrosivity category | C2 | C2 | C2 | C2 |
ISO 9223 - Standard deviation of corrosion rate [g/m² year] | ±3 | ±0.6 | ±0.1 | ±0.1 |
Parameter | Value | Measurment period | |
---|---|---|---|
Temperature [°C] | -0.2 | 2019-01-01 - 2020-01-01 | |
Relative humidity [%] | 77 | 2019-01-01 - 2020-01-01 | |
Total radiation [kWh/m² year] | 711 | 2019-01-01 - 2020-01-01 | |
Time of wetness [%] | 20 | τ3 | 2019-01-01 - 2020-01-01 |
RISE KIMAB AB, Box 7047, SE-164 07, Kista, Sweden Visiting address: Isafjordsgatan 28 A, Kista, Sweden
Carolina Schneiker (carolina.schneiker@ri.se), +46 10 228 48 61; Bo Rendahl (bo.rendahl@ri.se), +46 10 228 48 58
carolina.schneiker@ri.se