Site name:

SE, Gällivare

Country:

Sweden

Atmosphere:

Rural

Available space [m²]:

100

Altitude [m]:

300

Operational since:

2017

Subarctic test site located in the north of Sweden.

Corrosion category (ISO 9223)
ISO 9223 - Measurement period: 2018-10-01 - 2019-10-01
Measuring inputed: 2022/08/23
SteelZincCopperAluminium
ISO 9223 - Corrosion rate [g/m² year]384.41.70.3
Corrosivity categoryC2C2C2C2
ISO 9223 - Standard deviation of corrosion rate [g/m² year]±3±0.6±0.1±0.1
Environmental parameters
Parameter Value   Measurment period
Temperature [°C]-0.2 2019-01-01 - 2020-01-01
Relative humidity [%]77 2019-01-01 - 2020-01-01
Total radiation [kWh/m² year]711 2019-01-01 - 2020-01-01
Time of wetness [%]20τ32019-01-01 - 2020-01-01
Exposure racks
check_box
Exposure rack
check_box
Exposure rack
45°
check_box
Exposure rack
90°
check_box
Exposure rack
Customized
Contacts

RISE KIMAB AB, Box 7047, SE-164 07, Kista, Sweden Visiting address: Isafjordsgatan 28 A, Kista, Sweden

Carolina Schneiker (carolina.schneiker@ri.se), +46 10 228 48 61; Bo Rendahl (bo.rendahl@ri.se), +46 10 228 48 58
carolina.schneiker@ri.se