Site name:

PT, Lumiar

Country:

Portugal

Atmosphere:

Urban

Available space [m²]:

About 100 for placing test benches

Altitude [m]:

116

Operational since:

1990

Urban testing site located at the roof of a 2-floor building of LNEG with high U.V. exposure and corrosivity C2-C3. It is a RUV 3 test site, according to the classification of EN 10169-2. This OET is recognized by the European Coil Coating Association (ECCA) as a reference testing site since 1990: https://www.prepaintedmetal.eu/890/sites

Address: Laboratório Nacional de Energia e Geologia, IP (LNEG) - Campus do Lumiar, Estrada do Paço do Lumiar, 22, Edif. K2, 1649-038 Lisboa, Portugal
Corrosion category (ISO 9223)
ISO 9223 - Measurement period: 2014-01-01 - 2019-01-01
Measuring inputed: 2022/08/23
SteelZincCopperAluminium
ISO 9223 - Corrosion rate [g/m² year]1477120.2
Corrosivity categoryC2C3C3C2
ISO 9223 - Standard deviation of corrosion rate [g/m² year]±34±2±2±0.1
Environmental parameters
Parameter Value   Measurment period
Temperature [°C]17.3 2014-01-01 - 2019-12-01
SO2 [µg/m³]22P12014-01-01 - 2019-12-01
Chloride deposition [mg/m² day]18S12014-01-01 - 2019-12-01
Relative humidity [%]72 2014-01-01 - 2019-12-01
Total radiation [kWh/m² year]3311 NaN - NaN
Time of wetness [%]41τ42018-04-01 - 2019-12-01
Exposure racks
check_box
Exposure rack
check_box
Exposure rack
45°
check_box
Exposure rack
90°
check_box
Exposure rack
Customized
Additional information

Monitoring of atmospheric parameters: air temperature, relative humidity, solar irradiance, precipitation, wind speed and direction, time of wetness, with data collection every 10 seconds and storage every 10 minutes. Chloride deposition rate is evaluated by the wet candle method and sulfur dioxide deposition rate on lead dioxide sulfation plates (ISO 9225). The evaluation of the sulfur dioxide content in the atmosphere using a sensor is under development with data collection and storage, similarly to other parameters. The annual global radiation similar to that of Florida, but with a different distribution throughout the year. The cycle of UV radiation at Lumiar / Lisbon Test Site is best suited to the European location then that recorded in Florida, being thus more relevant for many European countries, and consequently for manufacturers of coil coated placing their products in these countries. The average annual temperature, as well as the annual distribution of temperature, relative humidity and rainfall are also more significant for European countries. Materials usually exposed: reference panels of different materials/metals, samples with organic coating, absorbers and reflectors surfaces, thermal solar collectors, polymeric materials, natural materials (e.g. wood), etc. Costs: Cost depends of samples dimensions and exposure time. Cost upon request.

Contacts

National Laboratory of Energy and Geology (LNEG) - Laboratory of Materials and Coatings (LMR), Estrada do Paço do Lumiar, 22, Edif. E, R/c, 1649-038 Lisboa – Portugal

Teresa Diamantino, teresa.diamantino@lneg.pt, +351 210 924 651
teresa.diamantino@lneg.pt