Exposure rack
5°
Roof of a 7-floor building located near the centre of Athens, capital of Greece, with about 5 million inhabitants.
ISO 9223 - Measurement period: 2017-11-01 - 2018-11-01 Measuring inputed: 2022/08/23 | Steel | Zinc | Copper | Aluminium |
---|---|---|---|---|
ISO 9223 - Corrosion rate [g/m² year] | 77 | 6.4 | 5 | 0.1 |
Corrosivity category | C2 | C3 | C2 | C1 |
ISO 9223 - Standard deviation of corrosion rate [g/m² year] | ±2 | ±0.3 | ±0.1 | ±0 |
Parameter | Value | Measurment period | |
---|---|---|---|
Rainfall [mm/year] | 448 | 2017-12-01 - 2018-11-01 | |
Temperature [°C] | 19.6 | 2017-12-01 - 2018-11-01 | |
SO2 [µg/m³] | 9 | P1 | 2017-12-01 - 2018-11-01 |
NOx [µg/m³] | 49 | 2017-12-01 - 2018-11-01 | |
pH of rain | 7.2 | 2017-12-01 - 2018-11-01 | |
Relative humidity [%] | 58 | 2017-12-01 - 2018-11-01 |
Climate Research Group, Section of Environmental Physics and Meteorology, Department of Physics, National and Kapodistrian University of Athens
Professor Costas Varotsos, covar@phys.uoa.gr, +2107276838
covar@phys.uoa.gr